We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Automatic Gas Sampling Device.
ipros is IPROS GMS ・ IPROS One of the largest technical database sites in Japan that collects information on.

Automatic Gas Sampling Device - List of Manufacturers, Suppliers, Companies and Products | IPROS GMS

Automatic Gas Sampling Device Product List

1~3 item / All 3 items

Displayed results

Automatic Gas Sampling Device GSP-311FT (Intrinsic Safety Explosion-Proof Structure)

Stable suction power even under high load! Moreover, it features a quiet design. It can suction various solid collection tubes as well as detection tubes.

<Features> ■ Capable of setting flow rates from 50 to 250 mL/min with detection tubes and other attachments ■ Automatic control of flow rate changes due to load fluctuations with constant flow function ■ Instantaneous flow and cumulative flow automatically corrected to values at 20°C ■ Sampling starts after a set time with automatic start function ■ Automatically stops based on installation time and volume, displaying cumulative flow and required time ■ Achieves pulsation-free suction with the configuration of the ventilation system ■ Dedicated detection tubes for 10-minute sampling for work environment measurement are available ■ Detection tubes for indoor environments, such as formaldehyde, are also usable ■ Various solid collection tubes, such as activated carbon tubes, are available ■ Intrinsically safe explosion-proof structure

  • Other environmental equipment
  • Other measurement, recording and measuring instruments
  • Other environmental analysis equipment
  • Automatic Gas Sampling Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Automatic Gas Collection Device GSP-400FT

With a flow rate setting of 50 to 1000 mL/min, it is possible to collect samples using the collection tube method outlined in the manual for measuring harmful air pollutants.

<Features> ■ Flow rate settings from 50 to 1000 mL/min, capable of collecting ethylene oxide, mercury and its compounds, acetaldehyde, and formaldehyde using the hazardous air pollutant measurement method manual. ■ Instantaneous flow accuracy of ±3% (during specified calibration), ensuring high precision. ■ Clear simultaneous display of flow rate and suction time. ■ Dustproof and drip-proof design (equivalent to IP54), providing safety even in rainy weather. ■ Continuous suction possible during power outages with backup power supply. ■ The collection tube attachment rotates, allowing the main unit to be installed at any angle. ■ Instantaneous flow and cumulative flow automatically corrected to values at 20°C or 25°C (user-defined setting).

  • Other environmental equipment
  • Other environmental analysis equipment
  • Automatic Gas Sampling Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Automatic Gas Collection Device GSP-500FT

It can suction detection tubes, activated carbon tubes, and silica gel tubes with stable suction power!

<Features> ■ Timer mode allows flow rate settings from 50 to 500 mL/min ■ Constant volume mode allows flow rate settings from 10 to 500 mL/min (10 to 49 mL/min is intermittent sampling at a suction flow rate of 50 mL/min) ■ Constant flow function automatically controls flow rate changes due to load variations ■ Simultaneous display of suction flow rate, suction time, and cumulative flow, allowing for easy confirmation at a glance without switching screens ■ Quiet design that minimizes operational noise ■ Automatic start function begins sampling after the set time ■ In program mode, up to 5 sampling conditions can be registered in advance ■ Instantaneous flow and cumulative flow are automatically corrected to values at 20°C or 25°C (user-defined setting) ■ With the optional lithium-ion rechargeable battery and automatic switching to dry batteries, it can be used for up to 110 hours (90 hours with lithium-ion battery + 20 hours with dry batteries / when using activated carbon tube 258-20 at a suction flow rate of 200 mL/min)

  • Other environmental equipment
  • Other measurement, recording and measuring instruments
  • Other environmental analysis equipment
  • Automatic Gas Sampling Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Related Categories of Automatic Gas Sampling Device